Menu

Javascript is not activated in your browser. This website needs javascript activated to work properly.
You are here

Species and epitope specificity of two 65 kDa glutamate decarboxylase time-resolved fluorometric immunoassays.

Author:
  • M Rui
  • CS Hampe
  • C Wang
  • Z Ling
  • FK Gorus
  • Åke Lernmark
  • DG Pipeleers
  • PE De Pauw
Publishing year: 2007
Language: English
Pages: 133-143
Publication/Series: Journal of Immunological Methods
Volume: 319
Issue: 1-2
Document type: Journal article
Publisher: Elsevier

Abstract english

The 65 kDa isoform of human glutamate decarboxylase (GAD65) is a major autoantigen in type 1 diabetes (T1D). In the present study, we have developed a sensitive sandwich time-resolved fluorescence immunoassay (TRFIA) for the quantification of GAD65 in cell extracts, cell media and serum. The monoclonal antibody GAD-6 is used to selectively capture GAD65 but not the slightly larger isoform GAD67, and the utilization of different detecting antibodies with distinct GAD65 epitope specificity allows modulating the specificity of the assay. To this effect we have biotinylated a recombinant antigen-binding fragment (rFab) with epitope specificity for the N-terminal region of rat and human GAD65 (rFab N-GAD65) and another rFab that selectively binds to the middle part of human GAD65 (rFab b96.11). In the assay the biotinylated rFabs are recognized by Europium labeled streptavidin. The obtained time-resolved fluorescence (TRF) is directly proportional to the concentration of GAD65 over a large measuring range (0.1 to > 100 ng/mL). Based on total error estimation including both bias and imprecision, the lower limit of quantitation (LLOQ) of GAD65 in cell extracts is 0.33 ng/mL with the N-GAD65 TRFIA, and 0.10 ng/mL with the b96.11 TRFIA, but the latter is suitable for human GAD65 only, whereas the N-GAD65 TRFIA has equal sensitivity with rat and human GAD65. Specificity was further checked with GAD65/67 fusion proteins, confirming that the presence of intact capture as well as detection epitope on the analyte is a prerequisite for recognition in both assays. We show that the beta cell-specific marker GAD65 can be quantified in pancreatic cell extracts and in serum, allowing studies on discharge during cell death in vitro as well as in vivo.

Keywords

  • Endocrinology and Diabetes
  • GAD65
  • Immunoassay
  • Type 1 diabetes
  • Pancreatic beta cells

Other

Published
  • Diabetes and Celiac Unit
  • ISSN: 1872-7905
E-mail: ake [dot] lernmark [at] med [dot] lu [dot] se

Principal investigator

Diabetes and Celiac Unit

+46 40 39 19 01

+46 70 616 47 79

60:11:015

Jan Waldenströms gata 35, Malmö

33

Lund University Diabetes Centre, CRC, SUS Malmö, Jan Waldenströms gata 35, House 91:12. SE-214 28 Malmö. Telephone: +46 40 39 10 00